ECalPro Instrumentation

DP Flow Element Sizing

Orifice plates, flow nozzles and venturi tubes per ISO 5167-2/-3/-4 (Reader–Harris/Gallagher) · three solve modes · validated <0.5% (methodology · orifice guide).

Mass flow, qm
18.2817 kg/s
β 0.58651 · C 0.60773 · Re_D 227536
PASS
β=0.587 within ISO 5167-2 validity 0.1–0.75.
E1.064995
epsilon1
area_m20.00282743
dP_kPa50
dPerm_Pa32147.54
dPerm_pct64.3
ReD227536
betaMin0.1
betaMax0.75
orifice-concentric · iso-5167-2:2003qm→ISO 5167-2 §5.1 mass-flow equation · C→ISO 5167-2 §5.3.2.1 Reader–Harris/Gallagher · epsilon→ISO 5167-2 §5.3.2.2 expansibility · dPerm→ISO 5167-2 §5.4.2 permanent pressure loss