Orifice plate sizing calculator — ISO 5167
Size differential-pressure flow elements per ISO 5167: concentric, eccentric and segmental orifice plates, ISA-1932 and long-radius nozzles, and classical venturi tubes. The concentric plate uses the Reader–Harris/Gallagher coefficient with a proper C↔Re iteration, and you can solve for flow, bore or ΔP. Every result is clause-cited and validated to <0.5% against the standard. It runs in the browser, offline once loaded.
Try it now
Mass flow, qm
18.2817 kg/s
β 0.58651 · C 0.60773 · Re_D 227536
β=0.587 within ISO 5167-2 validity 0.1–0.75.
E1.064995
epsilon1
area_m20.00282743
dP_kPa50
dPerm_Pa32147.54
dPerm_pct64.3
ReD227536
betaMin0.1
betaMax0.75
orifice-concentric · iso-5167-2:2003 — qm→ISO 5167-2 §5.1 mass-flow equation · C→ISO 5167-2 §5.3.2.1 Reader–Harris/Gallagher · epsilon→ISO 5167-2 §5.3.2.2 expansibility · dPerm→ISO 5167-2 §5.4.2 permanent pressure loss